Build plumbing networks with pumps, valves, and elbows; calculates Darcy-Weisbach friction loss, dynamic flow rate (GPM), and pressure drops.
Pipe friction, pump curves, and node pressure distributions
Calculates exact major pipe head loss and Swamee-Jain Colebrook-White friction factors across laminar and turbulent Reynolds regimes.
Visualize real-time velocity vectors, node pressure gauge readings, and pump head curves across complex looped plumbing networks.
Compare friction losses and flow rates across PVC, Drawn Copper, Commercial Steel, and Cast Iron with customizable fitting K-values.
Friction head loss is governed by $h_f = (f L / D) (v^2 / 2g)$, dropping with the fifth power of pipe diameter.
Fittings and valves introduce turbulent eddies calculated as $h_m = K (v^2 / 2g)$.
Pumping water vertically reduces pressure by 0.433 PSI per vertical foot of elevation rise.
Everything you need to know about Pipe Flow Simulator
The Darcy-Weisbach equation calculates head loss due to pipe friction: h_f = (f * L / D) * (v^2 / 2g). It depends on pipe length, diameter, flow velocity, and the dimensionless Darcy friction factor f.
Head loss is inversely proportional to the fifth power of pipe diameter (h_f ∝ 1/D^5). Doubling pipe diameter reduces velocity by 4x and friction loss by roughly 32x for the same flow rate.
Major losses occur from viscous friction along continuous pipe walls. Minor losses occur at localized disruptions like elbows, tees, valves, contractions, and expansions represented by resistance coefficient K.
Deepen your exploration of fluid dynamics, aerodynamics, and classical mechanics.
Simulate centrifugal booster pump performance, cavitation risks, and throttling control valve pressure drops.
For laminar flow (Re < 2000), f = 64/Re. For turbulent flow (Re > 4000), the simulator uses the Swamee-Jain explicit solution to the implicit Colebrook-White equation based on relative pipe roughness.
Cavitation occurs when fluid pressure drops below water's vapor pressure, causing vapor bubbles to form and violently collapse, eroding pump impellers. The simulator alerts you when suction pressure drops too low.
Yes! The simulator accounts for hydrostatic elevation changes (Z height in meters), subtracting roughly 0.433 PSI per foot of elevation rise (9.81 kPa/m).
Adjusting the valve opening percentage dynamically increases the minor loss coefficient K, restricting flow and creating a localized pressure drop across the valve.
Drawn Copper and PVC/PEX have extremely smooth interior walls (roughness e ≈ 0.0015 mm), creating significantly lower head loss than old Cast Iron (e ≈ 0.26 mm).
Yes! Click 'Export CSV' to download complete pipe velocities, Reynolds numbers, friction factors, head losses, and node pressures, or click 'Snapshot' for network diagrams.
The tool displays flow rates in US Gallons per Minute (GPM) and Liters per Second (L/s), velocities in meters per second (m/s), and pressures in Pounds per Square Inch (PSI).
Yes, it uses standard fluid mechanics formulas for sizing residential, irrigation, booster pump, and commercial HVAC chilled water pipe runs.
No software installation is required. The hydraulic network simulator executes entirely in your browser using HTML5 Canvas and TypeScript.